ABSTRACT
Objective To analyze the effects of exposure to simulated gastric juice on the mechanical properties and surface characteristics of resins used for partial and complete dentures.
Material and Methods Thirty discs of heat-polymerized, 3D-printed, and milled resins were fabricated and polished. Specimens were allocated into two groups according to the immersion medium: artificial saliva or simulated gastric juice. The degree of conversion of C=C bonds (DC) of heat-polymerized and 3D-printed resins was determined by Fourier-transform infrared spectroscopy. Surface characteristics were evaluated by surface roughness (Ra and Rz) and Knoop microhardness at baseline, 6 months and 1 year of exposure. Complementary scanning electron microscopy was performed. Roughness values were analyzed using the Friedman and Durbin–Conover tests, and microhardness by repeated-measures ANOVA and Tukey’s test (α = 0.05).
Results The degree of conversion was 85% for heat-polymerized resins and 65% for 3D-printed resins. At baseline, all materials exhibited relatively smooth surfaces with polishing marks. After exposure, surface morphology remained similar to the original, except for the heat-polymerized resin exposed to the acidic medium. Ra roughness was not affected by the immersion media (p = 0.449). However, time and material type significantly influenced microhardness (p = 0.002 and p < 0.001, respectively).
Conclusion Both immersion media reduced the microhardness of all resins. However, the extent of degradation caused by simulated gastric juice and artificial saliva was similar among heat-polymerized, milled, and 3D-printed resins.
KEYWORDS:
CAD-CAM; Complete denture; Gastric juice; Mechanical tests; Printing three-dimensional
RESUMO
Objetivo Analisar os efeitos da exposição ao suco gástrico simulado nas propriedades mecânicas e nas características de superfície de resinas utilizadas para próteses parciais e totais.
Material e Métodos Trinta discos de resinas termopolimerizadas, impressas em 3D e fresadas foram confeccionados e polidos. Os espécimes foram alocados em dois grupos de acordo com o meio de imersão: saliva artificial ou suco gástrico simulado. O grau de conversão das ligações C=C (DC) das resinas termopolimerizadas e impressas em 3D foi determinado por espectroscopia no infravermelho por transformada de Fourier. As características da superfície foram avaliadas por meio da rugosidade superficial (Ra e Rz) e da microdureza Knoop no início do estudo, após 6 meses e após 1 ano de exposição. Foi realizada microscopia eletrônica de varredura complementar. Os valores de rugosidade foram analisados utilizando os testes de Friedman e Durbin–Conover, e a microdureza por ANOVA de medidas repetidas e teste de Tukey (α = 0,05).
Resultados O grau de conversão foi de 85% para as resinas termopolimerizadas e de 65% para as resinas impressas em 3D. No baseline, todos os materiais apresentaram superfícies relativamente lisas com marcas de polimento. Após a exposição, a morfologia superficial permaneceu semelhante à original, exceto para a resina termopolimerizada exposta ao meio ácido. A rugosidade Ra não foi afetada pelos meios de imersão (p = 0,449). No entanto, o tempo e o tipo de material influenciaram significativamente a microdureza (p = 0,002 e p < 0,001, respectivamente).
Conclusão Ambos os meios de imersão reduziram a microdureza de todas as resinas. Entretanto, a extensão da degradação causada pelo suco gástrico simulado e pela saliva artificial foi semelhante entre as resinas termopolimerizadas, fresadas e impressas em 3D.
PALAVRAS-CHAVE:
CAD-CAM; Prótese total; Suco gástrico; Avaliação das propriedades mecânicas; Impressão tridimensional
INTRODUCTION
Edentulism, defined as the complete loss of natural teeth, remains a significant global public health concern, particularly among older adults. According to the World Health Organization, approximately 23% of adults aged 50 years or older are edentulous worldwide, highlighting the substantial burden of this condition in aging populations [1]. Individuals with edentulism frequently present comorbidities such as respiratory, mental, musculoskeletal, metabolic, and cardiovascular disorders. These medical conditions, along with the use of certain medications, have been linked to an increased risk of gastroesophageal reflux disease [2-4].
During regurgitation, gastric juice may reach the oral cavity, compromising dental tissues and restorative materials [2,5-8]. The contact of gastric juice with dental tissues can lead to erosion, and the subsequent demineralization and dentin exposure often require both direct and indirect restorations [9]. Regarding dental materials such as resin composites, surface degradation, increased roughness, and higher bacterial adhesion have been reported [10,11]. Although studies indicate that patients with gastrointestinal disorders exhibit a significantly higher rate of denture failure compared to individuals without these conditions [1-3], longitudinal data documenting the progression of these failures over time remain scarce.
The durability and surface characteristics of prosthetic materials may be compromised by a range of oral challenges, including staining [12] and microbial colonization [13,14]. In patients with gastrointestinal disorders, repeated exposure to acidic gastric content represents an additional risk factor that may accelerate material degradation. Currently, dentures can be fabricated using various methods, including conventional techniques with heat-polymerized acrylic resin, as well as digital workflows involving milling or 3D printing [15-17]. Despite being relatively recent, the latter two techniques have demonstrated clinical success [16,18], offering benefits such as fewer required appointments, improved retention, reduced operator dependency, and the ability to preserve digital records [19]. As a recent technique, there remains a lack of studies evaluating the effects of gastric juice on these materials, which are commonly used for the fabrication of denture teeth and bases.
Denture base materials are continuously exposed to the oral environment, where factors such as moisture, temperature fluctuations, and chemical challenges may contribute to their aging over time. Prolonged exposure to aqueous and acidic conditions can promote water sorption and hydrolytic degradation of the polymeric matrix, potentially affecting the structural stability and surface characteristics of these materials. These aging-related processes may compromise the long-term performance and clinical longevity of dentures, highlighting the importance of evaluating material behavior over extended periods [17-19].
Therefore, this study aimed to analyze the effects of simulated gastric juice on the mechanical properties and surface characteristics of materials used in the fabrication of denture bases and artificial teeth, with a focus on 3D-printed resins. It was hypothesized that exposure to gastric juice would significantly decrease the mechanical properties and increase surface roughness of these materials over time.
MATERIAL AND METHODS
Study design
This in vitro study evaluated three factors: manufacturing methods (in three levels: 3D-printed, milled, or heat-activated resin), immersion media (in two levels: simulated gastric juice or artificial saliva), and time (in three levels: baseline, 6 months, or 1 year). Evaluations of microhardness, roughness, and surface topography were carried out. The same specimens were evaluated over time for roughness and microhardness (repeated measures approach). Additionally, Fourier Transform Infrared Spectroscopy (FTIR) and Scanning Electron Microscopy analyses was performed. The sample size was determined based on a pilot study. The calculations were perfomed in a statistical website [20] using roughness (Ra) as the primary response variable. The mean difference and standard deviations considered were 0.2 and 0.1, respectively, with a desired power of 0.8, and α = 0.05, which resulted in a minimum of six specimens per group. The materials used in this study are described in Table 1.
Specimens’ preparation
Heat-polymerized acrylic resin (Lucitone, Dentsply Sirona, New York, USA) and 3D-printed resin (V-Print DentBase, VOCO, Cuxhaven, Germany) are indicated for denture bases, whereas the milled resin (CediTEC DT, VOCO, Cuxhaven, Germany) is indicated for the fabrication of artificial teeth. A total of thirty discs-shaped specimens (12mm in diameter and 2mm in thickness) were fabricated from the evaluated materials.
The Heat-activated acrylic resin samples were obtained by embedding printed model discs, made exclusively for this purpose. The printed specimens were molded with an impression material (Zetalabor®, Zhermack, Badia Polesine, Italy) in a dental flask for the fabrication of acrylic resin discs (Lucitone, Dentsply Sirona, New York, USA). Excess acrylic resin was removed during the muffle pressing process to prevent porosity from forming during this stage. The muffle furnace was then submerged in a water bath polymerization unit (polymerizer) until the material had polymerized completely. The polymerization cycle used for the specimens followed the manufacturer's recommendations for the Lucitone 550 acrylic resin (water bath: 90 minutes at 73 °C + 30 minutes at 100 °C).
For the 3D-printed resin specimens, the samples were designed using Rhinoceros 7.0 SR8 software (McNeel, North America, Seattle, USA). The models were exported as stereolithography (STL) files and imported into the printer slicing software (Composer 2.0), where the printing parameters were defined, including cylindrical support structures, a layer exposure time of 5.34 s, printing angle of 0°, and a layer thickness of 0.050 mm. The specimens were printed using a V-Print Dentbase resin (VOCO, Cuxhaven, Germany) with an ASIGA® MAX UV 385 printer (Asiga, Sydney, Australia), which operates using Digital Light Processing (DLP) technology. The printing process was conducted at a controlled temperature of 30 °C, and the specimens were positioned at a build orientation of 0°, parallel to the build platform, in order to standardize specimen fabrication and minimize the need for support structures. After printing, the specimens were cleaned in 96% isopropyl alcohol for 15 minutes in an ultrasonic bath to remove uncured resin residues, according to the manufacturer’s recommendations for this type of resin. The samples were then dried with absorbent paper and subjected to a post-polymerization process in an Otoflash® G171 photopolymerization unit (VOCO, Cuxhaven, Germany) using 2,000 flash pulses on each side of the specimen, totaling 4 minutes of post-curing.
The milled resin discs were made from a circular specimen cutter machine (MicroMil, Washington, USA), where cylinders were obtained (12 mm in diameter and 50 mm in length). The cylinders were then transferred to a precision cutter (Isomet 1000, Buehler, Lake Bluff, USA), where they were sectioned into 2-mm thick discs.
After manufacturing, all specimens were polished with abrasive papers of #400, #600, #1200, and #2000 grit in a polisher (Ecomet 250, Buehler, Lake Bluff, USA) under water cooling until reaching an average initial roughness (Ra) of 0.05 µm. Next, the samples were polished with a dry felt disk attached to a lathe (Nevoni, Barueri, São Paulo, Brazil) and an ultrafine diamond paste (Diamond Excel, FGM, Brazil)[CR1.1]. Finally, the specimens were cleaned in an ultrasonic bath with ethanol and dried in an oven at 37 °C for 48 minutes to allow evaporation of residual solvent and moisture prior to testing. The conditioning temperature was selected to approximate intraoral conditions, following recommendations for denture base polymers described in ISO 20795-1.
The specimens were divided into two experimental groups: exposed to artificial saliva or simulated gastric juice (0.113% hydrochloric acid in deionized water with pH of 1.2) [5]. The artificial saliva was prepared in a compounding laboratory and consisted of potassium chloride, sodium chloride, magnesium chloride, calcium chloride, carboxymethylcellulose, biodistilled glycerin, sorbitol, methylparaben (nipagin), and deionized water (H2O). The measured pH of saliva was 6.27, while that of simulated gastric juice was 1.99. For pH measurement, a DM-20 pH meter (Digimed, São Paulo, Brazil) was used, calibrated with standard solutions (Storage Solution for pH and electrodes, Hanna Instruments, Barueri, São Paulo, Brazil, Batch 7128) at pH 4.0 and 6.5. After calibration, three readings were taken for each of the evaluated liquids. The specimens were individually immersed in 3 mL of each liquid in a 24 well-plate in an incubator at 37ºC. The time points for evaluations were baseline (T0), 4 hours and 36 minutes (T1) and 9 hours and 12 minutes (T2), corresponding to 6 months and 1 year of clinical use, respectively [5]. At each exposure time, the samples were removed from the immersion media for being subjected to the analyses and were stored in distilled water during the analyses period.
Degree of C=C conversion
The heat-activated acrylic resin and the 3D-printed resin were had their degree of C=C conversion (DC) determined using Fourier-transform infrated (FTIR) spectroscopy (n=5). Spectral measurements of the specimens were first taken using a drop of the printed resin in its unpolymerized form, and the thermally activatedheat-polymerized acrylic resin was evaluated immediately following the mixing process. DC was quantified using the resolution of 4 cm-1 and 32 scans, using the absorbance method. Both resins were analyzed based on the peak at 1,637 cm-1, which are associated with aliphatic C=C bonds, corresponding to the methacrylic monomers (UDMA and TEGDMA). In the case of the studied impression resin, the composition includes the monomers urethane dimethacrylate (UDMA) and triethylene glycol dimethacrylate (TEGDMA), both containing highly reactive methacrylic groups, which are mainly responsible for the formation of the three-dimensional polymer network after light activation. The Equation 1 was used to calculate the degree of conversion (DC%) [21]:
where h0 and ht represent, respectively, the height of the absorption band corresponding to the reactive methacrylate group in relation to the baseline (or reference band), before the start of polymerization and after the curing time t. The reduction in this height over time reflects the conversion of the C=C groups of the methacrylic monomers (such as UDMA and TEGDMA) into single bonds during the formation of the polymer network.
Roughness analysis
Three measurements on each specimen (n = 16) were performed with a contact roughness tester (Surftest SJ 400, Mitutoyo, Tokyo, Japão). Three measurements were performed on the x-axis, and three were taken on the y-axis for each sample, using a cut-off of 0.80 mm, resolution 0.0001 μm (range of 8 μm), speed of 0.5 mm/s and total length of 4 mm (ISO 4287/1997). The parameters evaluated were the average roughness (Ra, μm) and the average of the five highest peaks and five deepest valleys (Rz, μm). The average of these three readings was used for the statistical analyses.
Knoop microhardness analysis
The Knoop microhardness was assessed using a microhardness tester (Shimadzu HMV-G21DT, Shimadzu, Kyoto, Japan). The polished surface of the discs (n=6) was subject to three indentations using a static load of 100 g for 30 seconds. The Knoop Hardness (KH) was calculated by the equation [2].
where P = applied load (kgf), A = surface area of the impression (mm2), L = impression length along the longest axis (mm), Cp = correction factor related to the shape of the indenter (0.070279).
Scanning electron microscopy
One representative specimen for each condition (n = 3) (T0, T1, and T2 exposed to artificial saliva and simulated gastric juice) were ultrasonically cleaned for 5 minutes, air dried, and gold-sputtered for 160 seconds at 40 mA (DentonVacuum Desk II). Then, they were analyzed using a scanning electron microscope (MEV, Inspect S50, FEI Company, República Tcheca) at 15 kV with a magnification of 3000× to evaluate the surface characteristics.
Statistical analysis
Statistical analysis was performed using the Jamovi software program (version 6.0, Sydney, Australia). Data were tested for homoscedasticity (Levene’s test) and normality (Shapiro-Wilk test). Ra and Rz values were evaluated using the Friedman test, with multiple comparisons using Durbin-Conover. Microhardness was evaluated using Repeated Measures ANOVA (time * material interaction), and multiple comparisons were evaluated using Tukey’s test.
RESULTS
Degree of C=C conversion
The FT-IR spectra (Figure 1a-1b) exhibited peaks corresponding to polymerized and unpolymerized heat-polymerized acrylic resin and 3D-printed resin. The degree of C=C conversion of the heat-polymerized acrylic resin revealed a conversion rate of 82% and 3D-printed resin base revealed a conversion rate of 65%.
- Fourier Transform Infrared Spectroscopy spectrum displaying the C=C stretching vibrations (1637 cm-1) of non-converted heat-polymerized acrylic resin and 3D printed resin. A: graph related to the milled resin. B: graph related to the printed resin.
Roughness
Table 2 describes the roughness results obtained for each experimental group. In this study, Ra was not affected by the immersion media (p=0.386), time (p=0.056), material (p=0.603), liquid*time (p=0.917), time*material (p=0.536), liquid*material (p=0.685), or time*liquid*material factors (p=0.449). On the other hand, Rz was affected by time (p=0.009) and the interaction between time and material (p=0.021), which revealed that the heat-polymerized material showed lower values after the 1-year immersion compared to the baseline.
- Means and standard deviation of roughness (Ra and Rz, μm). Obtained from each experimental group
Microhardness
Table 3 describes the results of microhardness. Time (p=0.002) and material (p<0.001) significantly influenced microhardness, showing significant statistical differences related to milled resin at different exposure times, when compared to other materials. All tested material had their microhardness values significantly decreased after T2 when compared to T0. However, milled resin achieved the highest results in all study times.
Scanning electron microscopy
Scanning electron microscopy analysis did not reveal evident surface topographical changes after exposure to artificial saliva or simulated gastric juice (Figure 2). Polishing marks were observed on the surfaces of all specimens.
- Scanning Electron Microscopy of the surfaces of Acrylic Resin, 3D printed and milled material before and after exposure, under 3000 x magnification. All specimens presented polishing marks, with no clear topographic differences between groups.
Discussion
Gastric juice did not affect the mechanical properties of the materials over time compared to artificial saliva; however, the milled material presented a superior mechanical behavior compared to 3D-printed and heat-polymerized resins. Based on these results, the tested hypothesis was rejected.
When different materials indicated for the fabrication of removable prostheses come into contact with an acidic substance (pH=1.99) and artificial saliva, a reduction in microhardness was observed over time for the 3D-printed and heat-polymerized resins. Previous studies have reported that polymeric materials subjected to simulated gastric juice do not exhibit significant changes in microhardness or mass loss, although surface roughness may be reduced or maintained [5]. In contrast, the findings of this study suggest that both acidic and neutral solutions can negatively affect all the resins studied herein over time, emphasizing the need for further investigations into their long-term stability in the oral environment. Both acidic and neutral solutions may negatively affect resin-based materials over time due to water sorption and hydrolytic degradation within the polymer matrix. The diffusion of water molecules into the polymer network may cause plasticization to increase chain mobility and weaken intermolecular interactions. Additionally, aqueous environments may promote hydrolysis of ester bonds and the leaching of residual monomers, which may gradually compromise the mechanical properties of the material [22,23].
When comparing the composition and technical processing of heat-polymerized, 3D-printed, and milled resins, notable differences become apparent. Milled polymethyl methacrylate (PMMA) has been reported to exhibit superior wear resistance and color stability compared to 3D-printed and conventionally processed PMMA [24]. This can be attributed to the fact that milled materials are produced industrially under controlled conditions. On the other hand, both acrylic and 3D-printed resins are typically fabricated in dental laboratories, where factors such as pre-processing, processing, and post-processing steps may significantly influence their final properties [25]. These factors include the degree of C=C conversion, which in our study was 65% for the 3D-printed resin, while for heat-polymerized acrylic resin a conversion rate of 82% was revealed. The degree of conversion of the milled material could not be determined; however, it is possibly higher than that of the heat-polymerized and 3D-printed materials due to controlled industrial manufacturing.
Although a reduction in microhardness was observed, signs of degradation were not visible in the scanning electron microscopy images. Hipólito and collaborators pointed out that this phenomenon can be explained by the inherent water sorption of resin-based materials, a process that is intensified in acidic environments [18]. Moreover, when a resin material undergoes the process of liquid sorption, its polymer matrix expands due to the separation of its polymer chains. This allows the acid corrosion to intensify over time, in addition to the natural degradation that dental materials experience in the oral environment [18]. Polymer expansion is caused by water sorption, which is determined by the polarity of PMMA molecules and the spaces between polymer chains created by residual monomers, as well as surface porosities in the resin that may also contribute to increased water sorption. Furthermore, the reduction in Rz observed in the heat-polymerized material might be associated with this polymer expansion occurring in PMMA [19,22].
The average roughness values reported from all tested materials fall within clinically acceptable limits (0.2 μm) [26] and all Ra values were below 0.5 μm, indicating that surface texture is unlikely to be perceptible or cause discomfort to patients. These favorable Ra values may contribute to reduced bacterial adhesion and biofilm formation [27,28], which is beneficial for oral health, particularly in immunocompromised individuals or those with poor oral hygiene [29]. However, one should note that this study simulated a maximum usage period of one year. Since removable prostheses are often used for longer durations, it remains uncertain whether prolonged exposure to gastric juice, combined with brushing, would degrade the materials and compromise their longevity.
This study also aimed to assess whether new materials developed for removable prostheses, such as printed and milled ones, are affected by gastric juice and artificial saliva. These materials behaved similarly and showed some degradation over time in moisture. Over the past few years, researchers have been studying methods to better process 3D-printed materials and obtain greater mechanical and optical properties [21,27,30,31]. For these materials, it is also suggested to test new protocols, such as combining mechanical and chemical oral hygiene methods, to verify their stability in relation to roughness and the impact of these attributes on the microhardness of the materials used. Additionally, new research should analyze fatigue resistance, which is also critical for prosthesis longevity.
This study provides novel insights into the effects of gastric juice on materials used for removable prostheses. Limitations of this study include the lack of thermal aging evaluation, which could have influenced outcomes related to roughness and microhardness. Future studies should incorporate thermocycling, mechanical loading, or brushing to better simulate intraoral conditions or perform in situ aging tests. Additionally, as gastric fluid composition varies among individuals, only one concentration of gastric juice can underestimate its effects on materials. Nonetheless, our findings suggest that gastric juice itself does not compromise the surface characteristics of heat-polymerized, milled, or 3D-printed resins for removable prostheses within one year of exposure. Further research is warranted to confirm these results.
CONCLUSIONS
Both gastric juice and saliva led to a decrease in the hardness of heat-polymerized, milled, and 3D-printed resins over time. However, the surface characteristics of these materials were not compromised by either immersion media throughout the experimental period.
Acknowledgements
The authors are thankful to the Brazilian Federal Agency for Coordination of Improvement of Higher Education Personnel (CAPES, finance code 0001) and to VOCO (Cuxhaven, Germany) for providing the material used in this research.
-
How to cite:
Santos LTP, Gonçalves NMF, Silva CML, Sousa PVS, Tôrres Neto AJ, Borges ALS, et al. Surface and microhardness alterations of denture materials following exposure to gastric juice. Braz. Dent. Sci. 2026;29:e5143. https://doi.org/10.4322/bds.2026.e5143
-
Funding
Not applicable.
-
Regulatory Statement
Not applicable.
Data availability
The data that support the findings of this study are available from the corresponding author upon reasonable request.
REFERENCES
-
1 Hunter E, Congdon N, de Moura Brito L, McKenna G, Petrauskiene E, Rodrigues Leles C, et al. The Global impact of edentulism: A systematic review. Eur J Public Health. 2023;33(Suppl 2):ckad160-1134. https://doi.org/10.1093/eurpub/ckad160.1134
» https://doi.org/10.1093/eurpub/ckad160.1134 -
2 Eusebi LH, Ratnakumaran R, Yuan Y, Solaymani-Dodaran M, Bazzoli F, Ford AC. Global prevalence of, and risk factors for, gastro-oesophageal reflux symptoms: A meta-analysis. Gut. 2018;67(3):430-40. https://doi.org/10.1136/gutjnl-2016-313589 PMid:28232473.
» https://doi.org/10.1136/gutjnl-2016-313589 -
3 Wang X, Wang Y, Bu Y, Liu Y, Gong S, Che G. Association of gastroesophageal reflux disease with the incidence of pulmonary disease. Front Cell Dev Biol. 2025;13:1552126. https://doi.org/10.3389/fcell.2025.1552126 PMid:40772230.
» https://doi.org/10.3389/fcell.2025.1552126 -
4 Zhou Z, Shen G, Zhou W, Gong J, Hu B. Causal relationships between modifiable risk factors and gastroesophageal reflux disease: a two-sample mendelian randomization study. Curr Med Chem. 2025;32. https://doi.org/10.2174/0109298673372983250710031732 PMid:40760758.
» https://doi.org/10.2174/0109298673372983250710031732 -
5 Cruz MEM, Simões R, Martins SB, Trindade FZ, Dovigo LN, Fonseca RG. Influence of simulated gastric juice on surface characteristics of CAD-CAM monolithic materials. J Prosthet Dent. 2020;123(3):483-90. https://doi.org/10.1016/j.prosdent.2019.04.018 PMid:31383520.
» https://doi.org/10.1016/j.prosdent.2019.04.018 - 6 Oliveira JJR, Cruz MEM, Dovigo LN, Fonseca RG. Long-term effects of simulated gastrijuice alternated with brushing on hardness, substance loss, flexural strength and reliability of CAD-CAM monolithic materials. J Appl Oral Sci. 2022;30:1-10.
-
7 da Cruz MEM, Oliveira JJR, Dovigo LN, Fonseca RG. Long-term effect of gastric juice alternating with brushing on the surface roughness, topography, and staining susceptibility of CAD-CAM monolithic materials. J Prosthet Dent. 2022;127(4):659.e1-11. https://doi.org/10.1016/j.prosdent.2022.01.016 PMid:35184887.
» https://doi.org/10.1016/j.prosdent.2022.01.016 -
8 Jiang S, Zheng L, Miao Z. Gastroesophageal reflux disease and oral symptoms: A two-sample Mendelian randomization study. Front Genet. 2023;13(January):1061550. https://doi.org/10.3389/fgene.2022.1061550 PMid:36685839.
» https://doi.org/10.3389/fgene.2022.1061550 -
9 Picos A, Badea ME, Dumitrascu DL. Dental erosion in gastro-esophageal reflux disease: a systematic review. Clujul Med. 2018;91(4):387-90. https://doi.org/10.15386/cjmed-1017 PMid:30564013.
» https://doi.org/10.15386/cjmed-1017 - 10 Somacal DC, Bellan MC, Monteiro MSG, de Oliveira SD, Bittencourt HR, Spohr AM. Effect of gastric acid on the surface roughness and bacterial adhesion of bulk-fill composite resins. Braz Dent J. 2022;33(6):94-102. PMid:36477970.
-
11 Tărăboanță I, Gelețu G, Stoleriu S, Iovan G, Tofan N, Tărăboanță-Gamen AC, et al. In vitro evaluation of gastric acid and toothbrushing effect on the surface state of different types of composite resins. Medicina. 2022;58(9):1281. https://doi.org/10.3390/medicina58091281 PMid:36143960.
» https://doi.org/10.3390/medicina58091281 - 12 Bonvicini M, Monaco C, Arena A, Consolo U, Silvestri D, Zicari F. Color stability of PMMA resins for complete dentures produced with CAD/CAM and 3D-Printing technologies: an in vitro study. Int J Prosthodont. 2025;38(3):365-73. PMid:39466614.
- 13 Manoil D, Wulfman C, Parga A. Candida albicans colonization on CAD-CAM denture resin surface. Journal of Dentistry. 2024;2025(157):1-6.
-
14 Poker BC, Oliveira VC, Macedo AP, Gonçalves M, Ramos AP, Silva-Lovato CH. Evaluation of surface roughness, wettability and adhesion of multispecies biofilm on 3D-printed resins for the base and teeth of complete dentures. J Appl Oral Sci. 2024;32:e20230326. https://doi.org/10.1590/1678-7757-2023-0326 PMid:38656049.
» https://doi.org/10.1590/1678-7757-2023-0326 -
15 Srinivasan M, Kalberer N, Fankhauser N, Naharro M, Maniewicz S, Müller F. CAD-CAM complete removable dental prostheses: A double-blind, randomized, crossover clinical trial evaluating milled and 3D-printed dentures. J Dent. 2021;115:103842. https://doi.org/10.1016/j.jdent.2021.103842 PMid:34637889.
» https://doi.org/10.1016/j.jdent.2021.103842 -
16 Silva GML, Silva SMA, Borba MTLM, Araujo AOS, Tôrres AJ No, Barreto LAL, et al. Effect of printing angle and aging of a 3D-printed resin for provisional prostheses: an in vitro study on fracture resistance. Braz Dent Sci. 2025;28(2):e4758. https://doi.org/10.4322/bds.2025.e4758
» https://doi.org/10.4322/bds.2025.e4758 - 17 Carneiro Pereira AL, Martins de Aquino LM, Carvalho Porto de Freitas RF, Soares Paiva Tôrres AC, da Fonte Porto Carreiro A. CAD/CAM-fabricated removable partial dentures: a case report. Int J Comput Dent. 2019;22(4):371-9. PMid:31840145.
-
18 Jurado CA, Tsujimoto A, Alhotan A, Villalobos-Tinoco J, AlShabib A. Digitally fabricated immediate complete dentures: case reports of milled and printed dentures. Int J Prosthodont. 2020;33(2):232-41. https://doi.org/10.11607/ijp.6305 PMid:32069350.
» https://doi.org/10.11607/ijp.6305 -
19 Alhallak K, Hagi-pavli E, Nankali A. A review on clinical use of CAD / CAM and 3D printed dentures. Br Dent J. 2023. https://doi.org/10.1038/s41415-022-5401-5 PMid:36624309.
» https://doi.org/10.1038/s41415-022-5401-5 -
20 Calculo Amostral [Internet]. Bauru: USP; 2026 [cited 2026 Abr 4]. Available from: http://estatistica.bauru.usp.br/calculoamostral/
» http://estatistica.bauru.usp.br/calculoamostral/ -
21 Lee EH, Ahn JS, Lim YJ, Kwon HB, Kim MJ. Effect of post-curing time on the color stability and related properties of a tooth-colored 3D-printed resin material. J Mech Behav Biomed Mater. 2022;126:104993. https://doi.org/10.1016/j.jmbbm.2021.104993 PMid:34871954.
» https://doi.org/10.1016/j.jmbbm.2021.104993 -
22 Backer AD, Münchow EA, Eckert GJ, Hara AT, Platt JA, Bottino MC. Effects of simulated gastric juice on CAD/CAM resin composites: morphological and mechanical evaluations. J Prosthodont. 2017;26(5):424-31. https://doi.org/10.1111/jopr.12420 PMid:26682954.
» https://doi.org/10.1111/jopr.12420 -
23 Gulakar TL, Comert GN, Karaman E, Cakan U, Ozel GS, Ahmet SO. Effect of simulated gastric acid on aesthetical restorative CAD-CAM materials’ microhardness and flexural strength. Niger J Clin Pract. 2023;26(10):1505-11. https://doi.org/10.4103/njcp.njcp_131_23 PMid:37929527.
» https://doi.org/10.4103/njcp.njcp_131_23 -
24 Elsharkawy YMM, Mohamed HT, El Saeedi TMAS, Farahat AMS. Comparative in vitro study on wear resistance and colour stability of 3D-printed, milled, and conventional PMMA denture teeth. BMC Oral Health. 2025;25(1):656. https://doi.org/10.1186/s12903-025-05983-7 PMid:40301879.
» https://doi.org/10.1186/s12903-025-05983-7 -
25 Menon RK, Xin YH, Wei BCT, AlSaqaf SO, Kariem AKA, Al Tabbaa MM, et al. CADCAM versus conventional denture bases: network meta-analysis of in vitro studies comparing accuracy and surface properties. Int Dent J. 2025;75(3):2062-70. https://doi.org/10.1016/j.identj.2024.12.032 PMid:39875278.
» https://doi.org/10.1016/j.identj.2024.12.032 -
26 Buergers R, Rosentritt M, Handel G. Bacterial adhesion of Streptococcus mutans to provisional fixed prosthodontic material. J Prosthet Dent. 2007;98(6):461-9. https://doi.org/10.1016/S0022-3913(07)60146-2 PMid:18061740.
» https://doi.org/10.1016/S0022-3913(07)60146-2 -
27 Kim D, Shim J, Lee D, Shin S, Nam N, Park KH, et al. Effects of post-curing time on the mechanical and color properties of three-dimensional printed. Polymers. 2020;12(11):2762. https://doi.org/10.3390/polym12112762 PMid:33238528.
» https://doi.org/10.3390/polym12112762 - 28 Rani V, Mittai S, Sukhija U. An in vitro evaluation to compare the surface roughness of glazed, reglazed and chair side polished surfaces of dental porcelain. Contemp Clin Dent. 2017;8(September):11-9. PMid:34220157.
-
29 Qiu J, Roza MP, Colli KG, Dalben YR, Maifrede SB, Valiatti TB, et al. Candida-associated denture stomatitis: clinical, epidemiological, and microbiological features. Braz J Microbiol. 2023;54(2):841-8. https://doi.org/10.1007/s42770-023-00952-0 PMid:36940013.
» https://doi.org/10.1007/s42770-023-00952-0 -
30 Finck NS, Fraga MAA, Correr AB, Dalmaschio CJ, Rodrigues CS, Moraes RR. Effects of solvent type and UV post-cure time on 3D-printed restorative polymers. Dent Mater. 2024;40(3):451-7. https://doi.org/10.1016/j.dental.2023.12.005 PMid:38129193.
» https://doi.org/10.1016/j.dental.2023.12.005 -
31 Neoh SP, Khantachawana A, Santiwong P, Chintavalakorn R, Srikhirin T. Effect of post-processing on the surface, optical, mechanical, and dimensional properties of 3D-printed orthodontic clear retainers. Clin Oral Investig. 2025;29(1):48. https://doi.org/10.1007/s00784-024-06120-4 PMid:39760896.
» https://doi.org/10.1007/s00784-024-06120-4
Edited by
-
Editor-in-chief:
Sergio Eduardo de Paiva Gonçalves
-
Editor:
Gabriel Kalil Rocha Pereira