| Lee et al.(30) |
Transducer: TDH-39 earphone, binaural presentation of the auditory stimuli. Type of auditory stimuli: white noise. Duration of auditory stimuli: 5 minutes. Intensity: 50, 60, 70, and 80 dB, presented in a random sequence, with 2-minutes intervals between intensities. |
Equipment: ECG, amplifier, and analog converter (Model SS1C). Sampling rate: 256 Hz. Duration of HRV measurements in the presence of auditory stimuli: 5 minutes. Indices measured: Frequency domain: VLF (< 0.04 Hz), LF (0.04-0.15 Hz), HF (0.15-0.40 Hz), and LF/HF. |
| Roque et al.(23) |
Transducer: insert earphones, binaural presentation of the auditory stimulus. Type of auditory stimulus: heavy metal and baroque musical styles. Duration of auditory stimulus: 4 minutes and 50 seconds and 5 minutes and 15 seconds. Intensity: approximately 70-80 dB, with 5-minute intervals between intensities. |
Equipment: Polar RS800CX heart rate monitor. Sampling rate: 1000 Hz. At least 256 RR intervals were used for analysis and only series with more than 95% sinus beats were included. Duration of HRV measurements in the absence of auditory stimuli: 10 minutes. Duration of HRV measurements in the presence of auditory stimuli: 5 minutes. Indices measured: Time domain: SDNN, pNN50, RMSSD. Frequency domain: LF (0.04-0.15 Hz), HF (0.15-0.40 Hz), and LF/HF. |
| Roque et al.(19) |
Transducer: insert earphones, binaural presentation of the auditory stimulus. Type of auditory stimulus: heavy metal, baroque musical styles and white noise. Duration of auditory stimulus: 4 minutes and 50 seconds, 5 minutes and 5 minutes and 15 seconds. Intensity: approximately 70-80 dB and 90 dB, with 5-minute intervals between intensities. |
Equipment: Polar RS800CX heart rate monitor. Sampling rate: 1000 Hz. At least 256 RR intervals were used for analysis and only series with more than 95% sinus beats were included. Duration of HRV measurements in the absence of auditory stimuli: 10 minutes. Indices measured: Groups 1 and 2 – Geometric analysis, Group 2 – Time domain and frequency domain. Time domain: SDNN, pNN50, RMSSD. Frequency domain: LF (0.04-0.15 Hz), HF (0.15-0.40 Hz), and LF/HF. Geometric analysis: RRTri, TINN, SD1, SD2, and SD1/SD2. |
| Amaral et al.(24) |
Transducer: insert earphones, binaural presentation of the auditory stimulus. Type of auditory stimulus: heavy metal and baroque musical styles. Duration of auditory stimulus: 4 minutes and 50 seconds and 5 minutes and 15 seconds. Intensity: blocks of 60-70 dB, 70-80 dB, and 80-90 dB, with 5-minute intervals between intensities. |
Equipment: Polar RS800CX heart rate monitor. Sampling rate: 1000 Hz. At least 256 RR intervals were used for analysis and only series with more than 95% sinus beats were included. Duration of HRV measurements in the absence of auditory stimuli: 10 minutes. Duration of HRV measurements in the presence of auditory stimuli: 4 minutes and 50 seconds. Indices measured: Time domain: SDNN, pNN50, RMSSD. Frequency domain: LF (0.04-0.15 Hz), HF (0.15-0.40 Hz), and LF/HF. |
| Amaral et al.(25) |
Transducer: insert earphones, binaural presentation of the auditory stimulus. Type of auditory stimulus: heavy metal and baroque musical styles. Duration of auditory stimulus: 4 minutes and 50 seconds and 5 minutes and 15 seconds. Intensity: blocks of 60-70 dB, 70-80 dB, and 80-90 dB, with 5-minute intervals between intensities. |
Equipment: Polar RS800CX heart rate monitor. Sampling rate: 1000 Hz. At least 256 RR intervals were used for analysis and only series with more than 95% sinus beats were included. Duration of HRV measurements in the absence of auditory stimuli: 10 minutes. Duration of HRV measurements in the presence of auditory stimuli: 4 minutes and 50 seconds and 5 minutes. Indices measured: Geometric analysis: RRTri, TINN, SD1, SD2, and SD1/SD2. |
| Silva et al.(27) |
Transducer: insert earphones, binaural presentation of the auditory stimulus. Type of auditory stimulus: heavy metal and baroque musical styles. Duration of auditory stimulus: 4 minutes and 50 seconds and 5 minutes and 15 seconds. Intensity: 64-85 dB, with 5-minute intervals between intensities. |
Equipment: Polar RS800CX heart rate monitor. Sampling rate: 1000 Hz. At least 256 RR intervals were used for analysis and only series with more than 95% sinus beats were included. Duration of HRV measurements in the absence of auditory stimuli: 10 minutes. Duration of HRV measurements in the presence of auditory stimuli: 5 minutes. Indices measured: Geometric analysis: RRTri, TINN, SD1, SD2, and SD1/SD2. |
| Silva and Guida(28) |
Transducer: insert earphones, binaural presentation of the auditory stimulus. Type of auditory stimulus: heavy metal and baroque musical styles. Duration of auditory stimulus: 4 minutes and 50 seconds and 5 minutes and 15 seconds. Intensity: 64-85 dB, with 5-minute intervals between intensities. |
Equipment: Polar RS800CX heart rate monitor. Sampling rate: 1000 Hz. At least 256 RR intervals were used for analysis and only series with more than 95% sinus beats were included. Duration of HRV measurements in the absence of auditory stimuli: 10 minutes. Duration of HRV measurements in the presence of auditory stimuli: 5 minutes. Indices measured: Geometric analysis: RRTri, TINN, SD1, SD2, and SD1/SD2. |
| Silva and Guida(28) |
Transducer: insert earphones, binaural presentation of the auditory stimulus. Type of auditory stimulus: heavy metal and baroque musical styles. Duration of auditory stimulus: 4 minutes and 50 seconds and 5 minutes and 15 seconds. Intensity: 64-85 dB, with 5-minute intervals between intensities. |
Equipment: Polar RS800CX heart rate monitor. Sampling rate: 1000 Hz. At least 256 RR intervals were used for analysis and only series with more than 95% sinus beats were included. Duration of HRV measurements in the absence of auditory stimuli: 10 minutes. Duration of HRV measurements in the presence of auditory stimuli: 5 minutes. Indices measured: Geometric analysis: RRTri, TINN, SD1, SD2, and SD1/SD2. |
| Amaral et al.(26) |
Transducer: insert earphones, binaural presentation of the auditory stimulus. Type of auditory stimulus: heavy metal and baroque musical styles. Duration of the auditory stimulus: unspecified. Intensity: blocks of 60-70 dB, 70-80 dB, and 80-90 dB. |
Equipment: Polar RS800CX heart rate monitor. Sampling rate: 1000 Hz. At least 256 RR intervals were used for analysis and only series with more than 95% sinus beats were included. Duration of HRV measurements in the absence of auditory stimuli: 10 minutes. Duration of HRV measurements in the presence of the auditory stimulus: 10 minutes. Indices measured: Time domain: SDNN, pNN50, RMSSD. Frequency domain: LF (0.04-0.15 Hz), HF (0.15-0.40 Hz), and LF/HF. |
| Nogueira et al.(29) |
Transducer: insert earphones, binaural presentation of the auditory stimuli. Type of auditory stimuli: heavy metal musical style. Duration of the auditory stimuli: 5 minutes and 15 seconds. Intensity: 75-84 dB, approximately. |
Equipment: Polar RS800CX heart rate monitor. Sampling rate: 1000 Hz. At least 1000 RR intervals were used for analysis and only series with more than 95% sinus beats were included. Duration of HRV measurements in the absence and presence of the auditory stimulus: 20 minutes each. Indices measured: Time domain: SDNN/RMSSD. Frequency domain: LF (0.04-0.15 Hz), HF (0.15-0.40 Hz), and LF/HF. Geometric analysis: RRTri, TINN, SD1, SD2, and SD1/SD2. |