Abstract
Background Nitrous Oxide (N2O) is a potent greenhouse gas with significant environmental impact and is currently the leading ozone depleting substance in use. Despite its long-standing role in anesthetic practice, data on N2O use and the environmental awareness of Brazilian anesthesiologists are scarce. This study aimed to describe patterns of N2O use and assess the level of awareness among anesthesiologists regarding its environmental impact.
Methods A nationwide cross-sectional survey was conducted among anesthesiologists in a private Brazilian hospital network. The questionnaire addressed the frequency of N2O use in adult and pediatric anesthesia, knowledge of its environmental effects, and attitudes toward its continued availability.
Results Of 1,238 eligible anesthesiologists, 941 completed the survey (response rate 76%). Overall, 59.3% (n = 558) reported never using N2O in adult patients, while 14.5% (n = 136) reported frequent or constant use. In pediatric patients, 27.5% (n = 259) reported never using N2O, and 38.9% (n = 366) reported frequent or constant use. Eighty percent (n = 753) indicated a reduction in N2O use since the beginning of their careers, and 34.5% (n = 325) were unaware of its contribution to climate change. Age and years of professional experience were directly proportional to N2O use in adults (p < 0.05), while awareness of its environmental impact was inversely associated with use in pediatric cases (p < 0.05).
Conclusion The survey demonstrates a shift toward reduced N2O use, particularly among younger anesthesiologists, although substantial use in adult practice remains. Persistent knowledge gaps highlight the importance of targeted education and policy interventions to mitigate environmental impact.
KEYWORDS
Anestesiologists; Climate change; General anesthesia; Nitrous oxide N2O; Occupational exposure
Introduction
The global average surface temperature has increased ∼1.1°C compared to pre-industrial levels. Projections indicate that surpassing a 1.5°C increase by 2050 may significantly hinder global capacity to adapt to the impacts of climate change.1,2 Within healthcare systems, inhaled anesthetics, particularly Nitrous Oxide (N2O), are recognized as substantial contributors to greenhouse gas emissions. According to the Intergovernmental Panel on Climate Change (IPCC), N2O is the third most prevalent anthropogenic greenhouse gas worldwide and has a global warming potential over 100 years (GWP₁₀₀) of 273, more than double that of sevoflurane (GWP₁₀₀ = 130).3 This high warming potential, combined with its status as the leading ozone-depleting agent currently in use, raises concerns about its unrestricted use in healthcare. Furthermore, N2O stands as the leading ozone-depleting agent currently in use.4
Despite its environmental implications, the clinical use of N2O in hospital settings is not comprehensively documented and understood, and its application spans various settings, from pediatric anesthesia to labor analgesia.5 A longitudinal study conducted in a 1,300-bed tertiary UK hospital revealed a significant decrease in N2O use over 12 years, yet a quarter of the physicians surveyed did not perceive it as a meaningful contributor to climate change.6 In the Brazilian context, recent data from a quality improvement initiative conducted in two quaternary hospitals in São Paulo demonstrated that targeted educational and structural measures, such as disconnecting anesthesia workstations from the central N2O pipeline, reduced anesthesia-related N2O CO2-equivalent emissions by 82.5% without adverse clinical effects.7 This example shows that significant emission reduction is feasible, reinforcing the importance of understanding current clinical practice patterns and practitioners’ level of awareness as a baseline for future interventions.
Recognizing anesthesiologists’ awareness of the environmental effects of inhalational anesthetics, particularly N2O, is crucial for guiding sustainable strategies, integrating eco-consciousness into medical training, and promoting routine emissions reporting.8,9 Furthermore, mapping current patterns of N2O usage can support targeted interventions aimed at reducing environmental footprint through evidence-based policy development.10 We hypothesized that awareness among anesthesiologists regarding the environmental impact of N2O remains limited and that clinicians with more years of clinical practice are more likely to continue its use. This could reflect a generational shift, with newer practitioners opting for alternatives to N2O. This study aimed to characterize the utilization patterns of N2O administration among anesthesiologists employed within a private hospital network in Brazil and to evaluate their understanding of its ecological impact.
Materials and methods
This was a nationwide, cross-sectional, observational web-based survey conducted across 72 private hospitals in Brazil between October 2 and November 2, 2024. At the time of data collection, no institutional policies or formal protocols restricting the use of N2O were in place in the participating hospitals. The study employed a nonprobability census sampling approach that included all anesthesiologists actively employed within the network during the data collection period who had an active institutional registration, a valid institutional email address, and departmental affiliation. Anesthesiologists who did not meet these criteria (including inactive or non-affiliated professionals) were excluded. Heads of departments were contacted directly and asked to forward the survey link, distributed via institutional email, to all eligible anesthesiologists. This process resulted in a total of 1,238 invitations. Participation was entirely voluntary and anonymous, and the survey proceeded only after informed consent was obtained.
The questionnaire was distributed through the leads of anesthesiology teams and department heads at 72 hospitals located across all five Brazilian macro-regions. These institutions represented the full hospital network operated by the private healthcare group involved in the research. While the network has national coverage, it is part of the private sector and therefore the sample does not necessarily reflect the distribution of anesthesiologists in the entire Brazilian healthcare system.
Surveys were completed via Google Forms® (Google, California, USA), enabling respondents to answer at their convenience. No identifying personal data beyond hospital affiliation was collected aside from hospital name; no individual selection or sampling techniques were applied, promoting a comprehensive and inclusive collection of perspectives. Respondents were unable to modify their previous answers, and the survey could not be paused and resumed later. Only fully completed questionnaires were considered for the final analysis. The estimated questionnaire completion time was 3 minutes. To ensure data integrity, responses originated from duplicate IP addresses were evaluated and excluded when confirmed. Additionally, responses completed in under 30 seconds from a single IP address were considered non-engaged and were removed from the dataset.
Questionnaire design
The questionnaire was designed collaboratively by four anesthesiologists affiliated with the network’s quality improvement department. Content validity was established through review by a panel of six anesthesiologists with expertise in clinical anesthesia, environmental sustainability, and quality improvement. The survey was then conducted with ten anesthesiologists from the same hospital network who were not included in the final analysis. This pilot test evaluated the clarity of questions, estimated completion time, and technical performance of the online survey tool. Minor adjustments were made before the final distribution. The survey was tested according to previously published guidelines.11 To maintain objectivity and reduce interpretive bias, the questionnaire employed close-ended, multiple-choice formats.
Based on the American Society of Anesthesiologists’ (ASA) guidelines on environmentally sustainable anesthesia12 and other key publications addressing environmental sustainability in the perioperative setting,1,13,14 we developed a structured survey aimed to explore the frequency and profile of N2O utilization, as well as to assess the level of knowledge regarding its environmental impact. The frequency of N2O use in inhalational anesthesia for both adult and pediatric patients was assessed using a five-point Likert scale with the options “Never”, “Rarely”, “Sometimes”, “Often”, and “Always”. The final questionnaire comprised 17 items, divided into five sections: 1) Frequency of use in adult and pediatric patients (Questions 6‒8); 2) Fresh gas flow determination during inhalational induction (Question 9); 3) Frequency with which respondents had observed gas flow meters left open after the completion of anesthesia and when the anesthesia workstation was no longer in use (e.g., post-transport, during room turnover, or prior to initiating a subsequent anesthesia) (Question 10); 4) Perception of N2O environmental impact, specifically related to global warming and ozone depletion (Questions 11‒14); 5) Patterns in N2O clinical use and the underlying motivations for its reduction or discontinuation (Questions 15‒17). The questionnaire was developed in Portuguese (Supplementary Tables 1‒2). The primary endpoint was the self-reported frequency of N2O use in adult and pediatric anesthesia. Secondary endpoints included awareness of N2O’s environmental impact and attitudes toward its continued availability. Potential harm and/or adverse events were not applicable to this survey-based study.
This study followed the Checklist for Reporting Results of Internet E-Surveys (CHERRIES),15 the EQUATOR-endorsed guideline for the design and reporting of web-based surveys (see Supplementary Material for the completed checklist). All procedures involving human participants were conducted in compliance with the ethical standards established by the institutional and national research committees, as well as the principles of the Declaration of Helsinki. This study was approved by the Institutional Research Ethics Committee (Protocol n° 7,023,106; CAAE 82170024.0.0000.0087), and the approval can be verified through the public registry at Plataforma Brazil: https://plataformabrasil.saude.gov.br/visao/publico/indexPublico.jsf.
Statistical analysis
To ensure that the number of responses would be sufficient for the planned analyses, we calculated a minimum required sample size of 294 participants using the formula , where n represents the sample size, Z is the Z score corresponding to a 95% confidence level, p is the estimated population proportion, and E is the margin of error set at 5%. Anticipating an overall survey response rate between 40%‒60% (based on previous institutional survey experience and published literature on physician survey participation), we invited all eligible professionals (n = 1,238). Only fully completed questionnaires were included in the final analysis. Incomplete or partially completed questionnaires were excluded from all analyses; therefore, no imputation for missing data was performed. Responses completed in less than 30 seconds from the same IP address were considered non-engaged and excluded from the dataset. A total of six questionnaires met these criteria and were removed from the analysis.
Data normality distribution was assessed using the Shapiro-Wilk test. Categorical variables were analyzed using the Chi-Square test to compare proportions. Continuous variables were expressed as means and standard deviations for normally distributed data, or as medians with interquartile ranges otherwise. Non-parametric data were analyzed using the Kruskal-Wallis test for comparisons involving three or more categories, followed by Dunn’s post hoc method for multiple comparisons when p < 0.05, and the Mann-Whitney U test for comparisons between two categories. Adjusted associations between the self-reported frequency of N2O administration in adult and pediatric anesthesia (“occasionally”, “frequently” or “always”) and clinician characteristics were quantified as Odds Ratios (OR) with 95% Confidence Intervals (95% CI). Clinician characteristics included age, years of professional experience, geographic region, and the respondent’s belief that N2O contributes to climate change. Multivariable logistic regression was performed with simultaneous entry of all covariates. A 95% CI and p-value < 0.05 represented statistical significance. All analyses were conducted using R software version 3.4.4 (R Foundation for Statistical Computing, Austria).
Results
All 72 hospitals contacted agreed to participate in the survey, and a total of 941 anesthesiologists answered the questionnaire, yielding a completion rate of 76%. The flow of participants, including invitations, exclusions, and the final analytical sample, is shown in Figure 1. The median age of the participants was 40 (35‒49) years, with a median time of 10 (5‒21) years since completing medical residency (Supplementary Figs. 1‒2).
Study flow diagram showing the number of anesthesiologists invited, responses received, exclusions, and the final analytical sample.
A five-point Likert scale was applied to assess the frequency of N2O use in inhalational anesthesia for both adult and pediatric patients. Regarding adult patients, 59.3% (n = 558) of respondents reported never using N2O, and 5.8% (n = 55) reported frequent use (Fig. 2). Age and years of experience were directly proportional to the frequency of N2O use in adult patients (p < 0.05; Table 1). There was a significant difference in the proportion of responses indicating the use of N2O among adult patients by geographic location, with the Southeast (14.2%) and South (14.9%) regions reporting the highest rates of “always”, “frequently”, and “occasionally” use (p = 0.009) (Fig. 3; Supplementary Table 3). Among those who reported N2O use in adult patients (n = 383), 15.1% (n = 58) indicated its use for inhalational sedation, and 3.4% (n = 13) for labor analgesia.
Frequency and profile of nitrous oxide usage, and assessment of anesthesiologists' knowledge regarding the environmental impact of this gas in a network of 72 private hospitals in Brazil: Differences by age (years) and years of professional experience since completion of medical residency in anesthesiology.
Distribution of respondents' reported frequency of N2O use in adults and pediatric patients.
Heatmap of geographical distribution of respondents by frequency of N2O use in adults and pediatric patients (occasionally, frequently, or always).
The use of N2O in pediatric anesthesia was reported by 34% (n = 320) of participants (Fig. 2). Unlike in adult practice, neither age nor professional experience were associated with N2O use in pediatric patients (p > 0.05; Table 1). There was no difference in the frequency of N2O use in pediatric patients across geographic regions (p = 0.38).
Regarding the method for defining Fresh Gas Flow (FGF) during inhalational induction, FGF based on patient weight (∼120 mL/kg/min-1) was reported by 35.9% (n = 338), while 27% (n = 334) indicated using an FGF of 10 L/min or more, regardless of the patient's weight (Table 1). Thirty seven percent (n = 349) based their FGF on clinical assessment at the time of induction. At the conclusion of anesthesia, the practice of verifying whether the gas flow meter has been properly shut off plays a critical role in minimizing wastage, whether oxygen or inhalational agents. Respondents were inquired about how often they observed gas flow meters left open after anesthesia had ended and when the anesthesia workstation was no longer in use (e.g., post-transport, room turnover, or prior to subsequent anesthesia). Twenty-nine percent (n = 273) of anesthesiologists reported frequently or always witnessing gas flow meters left open and unused, whereas only 5.8% (n = 55) stated they had never witnessed this practice.
In response to questions about the environmental consequences of inhalational agents such as N2O and their contribution to climate change through global warming, 34.5% (n = 325) reported being unaware of any relationship between anesthetic technique and climate change. Seasoned anesthesiologists were more likely to be unaware of this link (p < 0.05). Only 35.8% (n = 337) correctly identified that N2O persists in the environment for over 100 years (Table 2).
Longitudinal changes in nitrous oxide usage, access to N2O in operating rooms and trends in N2O use, in a network of 72 private hospitals in Brazil: differences by age and years of professional experience since completion of anesthesia residency.
When comparing current practices with those at the beginning of their careers, 80% (n = 755) reported a reduction in the use of N2O over time. Half of the respondents, 50.7% (n = 477), stated that N2O should not be freely or readily available (Table 2). When asked about future use, 48% (n = 452) of respondents either reported not currently using N2O or indicated they intended to discontinue its use in the short term. In contrast, 27.8% (n = 262) stated they intended to continue using it. There was no significant association between these responses and either age or years of professional experience (p > 0.05).
The main reasons cited for reducing or discontinuing N2O use were increased incidence of nausea and vomiting (51.9%, n = 489), greater adoption of Total Intravenous Anesthesia (TIVA) (54.2%, n = 510), respiratory adverse effects such as hypoxia and atelectasis (21.1%, n = 199), its contribution to global warming and ozone layer depletion (32.2%, n = 303), pollution and occupational exposure in the operating room (37.0%, n = 349), and the perception that its clinical benefit is negligible (21.3%, n = 201). Most respondents (70%, n = 657) indicated that the withdrawal of N2O would not impact their anesthetic technique. There was no significant association between this perception and respondents’ age or years of professional experience regarding the impact on their anesthetic technique (p > 0.05; Table 2).
In the multivariable logistic model constructed to examine determinants of self-reported N2O use (“occasionally”, “frequently”, or “always”), age ≥ 50 years remained independently associated with N2O use in adult patients (adjusted OR = 2.99, 95% CI 1.95‒4.59) (Table 3). By contrast, the conviction that N2O aggravates climate change showed an inverse relation with use in adults (adjusted OR = 0.42, 95% CI 0.29‒0.61) and constituted the sole significant predictor in pediatric anesthesia (adjusted OR = 0.41, 95% CI 0.31‒0.54). Years of professional experience and geographic region did not achieve significance in either model.
Adjusted odds ratios (95% CI) from multivariable logistic regression of clinician characteristics associated with self-reported nitrous oxide administration (“occasionally”, “frequently” or “always”) in adult and pediatric anesthesia.
Discussion
This study characterized patterns of N2O use in anesthesia and identified gaps in anesthesiologists’ awareness of its environmental impact. Eighty percent of respondents reported a reduction in use since the beginning of their careers, and nearly half expressed reservations about its unrestricted availability. In contrast, 34.5% of anesthesiologists were unaware of its role in climate change. These patterns may be related to differences in training exposure, evolving clinical preferences, or increasing awareness of sustainability issues in more recent generations of practitioners. Given the cross-sectional nature of this study, these factors should be interpreted as possible contributors rather than causal determinants.
Understanding these usage patterns is essential for informing strategies aimed at sustainable environmental impact. Our results support the development of targeted practice protocols aimed at curtailing N2O use, particularly in cases where its clinical benefits are outweighed by alternative anesthetic agents/techniques. Additionally, reports of frequent gas flow meter misuse after procedures (29%) suggest inefficiencies that warrant attention, as they may result in unnecessary emissions and resource waste.16 If N2O consumption is minimal and not critical for clinical practice, healthcare leaders should reassess the need to maintain N2O supply infrastructure and focus on interventions aimed at optimizing consumption patterns.17,18
In a Brazilian quality improvement initiative for adult patients, baseline data over the 16-week pre-intervention period indicated an average N2O usage rate of 11%, decreasing to 2% post-intervention.7 Considering these results, the use of N2O in adult patients remains a prevalent practice, and a cultural shift is necessary to reduce its usage in more restricted contexts, such as the inhalational induction of pediatric patients.6,8 In pediatric anesthesia, targeted quality improvement interventions have shown substantial environmental benefits. In a 20-month project involving over 33,000 inhalational inductions, reducing N2O use from 80% to less than 20% and lowering FGF by 28% was achieved through education, expert engagement, and visual reminders, without affecting induction times or patient behavior.8 This suggests that even minor regulatory or logistical barriers could substantially reduce N2O use.5,19
The practice of using high FGF during inhalational induction was also analyzed. High FGF is often employed to hasten induction or to compensate for mask leaks during facemask ventilation. However, this practice results in the consumption of large quantities of volatile agents, almost all of which are wasted directly into the environment.20 Strikingly, less than 40% of anesthesiologists regulate FGF based on the patient's weight, even though exceeding the minute-ventilation does not meaningfully accelerate induction and leads to significant volatile agent consumption.21 Since minute-ventilation is correlated with the patient's weight, the Society for Pediatric Anesthesia (SPA) recommends using a weight-based minimum safe and effective FGF of 0.15 L/min/kg during inhalational induction.22 This recommendation includes a safety margin to ensure no rebreathing and accounts for differences between anesthesia delivery systems and individual patient variation.8 However, our data demonstrated that pediatric anesthesiologists often used fixed high FGF (e.g., 10 L/min of oxygen and N2O, with or without sevoflurane), regardless of patient's size, contradicting best practices and exacerbating environmental impact. Coupled with prior studies indicating that elevated FGF during induction is correlated with increased sevoflurane consumption and higher FGF levels throughout cases, these results underscore the importance of adopting an optimized and environmentally sustainable approach to anesthetic management.14,23
Data from Italy align with our observations, showing a gradual reduction in the use of inhalational agents and a persistent lack of awareness of environmental issues among anesthesiologists.24 Indeed, the majority of anesthesiologists stated that TIVA could replace anesthetic gases in more than 40% of cases, while only 5% believed this could happen in less than 20% of cases.24 Similarly, 65% of anesthesiologists were partially or completely unaware of the environmental impact of anesthetic gases, and the use of high FGF remains a common practice in inhalational anesthesia.24 Similar to the reduction observed in our study, a longitudinal evaluation in a 1,300-bed tertiary hospital in the United Kingdom demonstrated a marked decline in N2O use over 12 years, indicating that the decrease in N2O utilization is not limited to Brazil; however, in that UK cohort, one quarter of physicians did not recognize it as a significant contributor to climate change.6
Senior anesthesiologists were more likely to report frequent N2O use in adult patients, although no significant generational difference was observed in pediatric use. There were no differences in age or professional experience regarding the perception of its impact on anesthetic technique or the tendency to reduce its use. This suggests that, despite the historical use of N2O among more senior anesthesiologists, they may be open to reducing its utilization, with unwanted clinical effects being the main driver for limiting its use. This contrasts with results from the UK, where environmental impact was the primary reason for reducing N2O use.6 Such differences imply that “green anesthesia” remains in early stages in Brazil, despite global acknowledgement of climate change as “the biggest threat to global health in the 21st century”.
Our results delineate a marked generational gradient in practice patterns: anesthesiologists aged ≥ 50-years were nearly three times more likely to administer N2O to adult patients, whereas acknowledging its climate impact was inversely associated with use and remained the sole significant determinant in pediatric anesthesia. One plausible explanation is that sustainable practice is still insufficiently embedded in medical training: the environmental knowledge gap among senior educators hampers the transmission of sustainability principles to trainees, creating a persistent barrier to behavior change. Accordingly, environmental stewardship should be formally integrated into residency curricula and continuing professional development for practicing anesthesiologists, as multiple studies across different countries have already advocated.24,25
Several factors may influence the discontinuation of N2O use in Brazil, operating as either barriers or drivers of change. Cultural barriers include the long-standing tradition of using N2O for pediatric inhalational induction and the absence of environmental sustainability as a structured component of anesthesiology training. Institutional barriers involve the persistence of central pipeline supply systems (which are often faulty/leaky) and the lack of infrastructure modifications needed to reduce systemic losses. Educational barriers stem from limited exposure to concepts of sustainable anesthesia and occupational safety related to anesthetic gases during both residency and continuing professional development. On the other hand, important drivers for reducing N2O use include the growing global and national emphasis on climate change mitigation, the increasing availability and familiarity with TIVA, and awareness of the occupational hazards associated with waste anesthetic gases. Evidence from successful Brazilian initiatives, such as the 82.5% reduction in N2O emissions achieved in two quaternary hospitals through targeted education and pipeline disconnection, reinforces the feasibility of large-scale change.7 These national experiences, in line with the global trend toward N2O phase-out, highlight that meaningful reductions are possible when clinical engagement is combined with infrastructure and policy interventions.7,9,26,27
Despite consistent evidence that occupational exposure to inhalational anesthetics, particularly in operating rooms without active scavenging systems, exceeds international safety limits and poses health risks,28,29 only 37% of respondents in our study cited pollution or occupational exposure as a reason to reduce N2O use. This underestimation is particularly concerning since longitudinal evidence shows that such exposures are not merely theoretical risks.30 A prospective study evaluating young physicians before, during, and at the end of their medical residency demonstrated that working in unavenged operating rooms leads to substantial exposure to inhalational anesthetics, resulting in lipid and protein oxidation, oxidative DNA damage, impairment of antioxidant systems, modulation of gene expression involved in DNA repair, and measurable genotoxic effects.31 Our results suggest a significant gap in awareness or a tendency among anesthesiologists to underestimate the occupational hazards associated with waste anesthetic gases in the operating room and/or global environment.
The results of this study have relevant implications for policy, education, and clinical practice in Brazil. In the educational sphere, environmental stewardship and occupational safety related to anesthetic gases should be incorporated into undergraduate, residency, and continuing medical education curricula to build awareness from the earliest stages of training. In clinical practice, dissemination of best practices for optimizing FGF, greater adoption of TIVA when clinically appropriate, and institution-led quality improvement programs can collectively contribute to reducing N2O emissions. Aligning these strategies with international sustainability goals offers a pathway for Brazilian anesthesiology to achieve measurable environmental impact reduction without compromising patient care.12,24,25
Contemporary guidance from professional societies and health systems increasingly supports the reduction of nitrous oxide use and the decommissioning of centralized piped N2O systems, primarily due to their disproportionate contribution to emissions through chronic leakage. The World Federation of Societies of Anaesthesiologists and partner organizations have endorsed principles of environmentally sustainable anesthesia that include minimizing or eliminating routine N2O use, optimizing fresh gas flows, and addressing avoidable infrastructural losses.1 More recent consensus from the United Kingdom and Ireland recommend the removal of piped N2O manifolds and transition to point-of-use cylinders, driven by data indicating that a substantial proportion of N2O supplied via pipelines may be lost to leakage before reaching patients, thereby generating emissions with minimal clinical benefit.6,18 Similar action plans and toolkits from NHS systems and other jurisdictions highlight N2O mitigation as a priority, emphasizing leak detection, decommissioning of underused manifolds, and alignment with net-zero strategies.17,32 These positions are consistent with analyses showing that N2O is a long-lived greenhouse gas and a leading ozone-depleting substance, and that infrastructural waste rather than conscious clinical use can account for a large share of its footprint.4 In this context, the reduction in self-reported N2O use observed among Brazilian anesthesiologists ‒ particularly the limited perceived dependence on N2O for routine practice ‒ supports the feasibility of targeted institutional policies and infrastructure reviews aimed at rationalizing or discontinuing N2O supply where clinically appropriate, while maintaining patient safety.
Our results should also be interpreted in light of the evolving Brazilian regulatory framework for medical gases. ANVISA RDC n° 870/2024 and Normative Instruction n° 301/2024, n° 301/2024 classify medicinal gases, including N2O, as regulated medicinal products and establish contemporary requirements for notification, registration, and quality assurance, with defined implementation timelines.33,34 Within this framework, hospitals are expected to ensure that centralized medical gas systems and gas mixers comply with technical standards such as ABNT NBR 12188 (centralized medical gas pipeline systems) and ABNT NBR 15882 (oxygen-nitrous oxide gas mixers). Decisions to maintain, rationalize, or decommission centralized N2O infrastructure should follow these standards, be guided by documented low clinical demand, robust safety assessments, and leak prevention, and be integrated into broader environmental sustainability and patient safety strategies.35,36 While our survey did not directly audit regulatory compliance or engineering practices, the observed trend toward reduced N2O use among Brazilian anesthesiologists is consistent with and supportive of this regulatory direction.
This study has limitations. First, the web-based design and voluntary participation introduce potential selection bias, as the sample was drawn from a convenience census of eligible anesthesiologists and relied on self-reporting, which may not reflect actual clinical behavior. Second, although the sample size calculation was appropriately performed and largely exceeded, with 941 completed questionnaires and a high response rate of 76%, the study employed a nonprobability sampling approach restricted to anesthesiologists from a private hospital network in Brazil. This may limit the generalizability of the results to other healthcare systems, including public hospitals and rural settings. Third, the questionnaire was not formally validated through psychometric testing, which may affect the reliability and reproducibility of the results, although content review by experts was performed before distribution. Fourth, social desirability bias may have influenced responses, particularly for items related to environmentally responsible behaviors. Fifth, the absence of objective data or verification regarding the actual use of N2O limits the ability to validate self-reported information. Sixth, the study did not collect information on the surgical case mix of each participating hospital, which could influence N2O usage patterns, as hospitals with surgical profiles less likely to require N2O, such as those without pediatric, obstetric, or specific inhalational sedation cases, might have contributed disproportionately to lower reported usage rates. Lastly, the cross-sectional design and absence of longitudinal follow-up prevent the assessment of temporal trends and causality, and other potentially relevant variables, such as institutional policies, availability of TIVA, or local anesthetic protocols, were not examined.
Conclusion
This national survey identified reduced N2O use among younger anesthesiologists, suggesting evolving practice patterns potentially driven by changes in training, increased familiarity with alternative anesthetic techniques, and heightened awareness of occupational and environmental considerations. However, a substantial proportion of practitioners, particularly older anesthesiologists, remain unaware of N2O’s long atmospheric lifetime and its role in global warming. Addressing this knowledge gap through targeted educational strategies, coupled with evidence based institutional and national policies, could support the optimization of N2O use while reducing its environmental footprint. The fact that half of the respondents questioned its continued unrestricted availability underscores the opportunity for policy makers to act. Future research using validated instruments and nationally representative samples will be essential to confirm these results and inform sustainable anesthesia practices in Brazil and beyond.
Data availability statement
The anonymized dataset analyzed during the current study is available from the corresponding author upon reasonable request.
Disclosure statement
This study did not receive or require any funding sources. The authors have no commercial or non-commercial affiliations representing potential conflicts of interest, nor do they have any associations with consultants of any type.
Ethics statement
This investigation was approved by the São Luiz & Rede D’Or Hospitals Research Ethics Committee (Protocol number 7,023,106; CAAE 82170024.0.0000.0087). The approval can be verified through the official public registry at Plataforma Brazil: https://plataformabrasil.saude.gov.br/visao/publico/indexPublico.jsf.
Previous presentation in conferences
This work was presented at the IV International Symposium on Quality and Safety Rede D’Or ‒ 7th Quality Annual Meeting (12-14 September 2025, Salvador, BA, Brazil).
Declaration of generative AI in scientific writing
The authors did not use generative artificial intelligence in the preparation of this manuscript.
Supplementary materials
Supplementary material associated with this article can be found in the online version at doi:10.1016/j.bjane.2026.844739.
Supplementary materials
References
- 1 White SM, Shelton CL, Gelb AW, et al. Principles of environmentally-sustainable anaesthesia: a global consensus statement from the World Federation of Societies of Anaesthesiologists. Anaesthesia. 2022;77:201-12.
- 2 Watts N, Adger WN, Agnolucci P, et al. Health and climate change: policy responses to protect public health. The Lancet. 2015;386:1861-914.
- 3 The Intergovernmental Panel on Climate Change (IPCC). Sixth Assessment Report Working Group I Climate Change 2021: The Physical Science Basis ‒ Summary for Policymakers.
- 4 Ravishankara AR, Daniel JS, Portmann RW. Nitrous Oxide (N2O): The Dominant Ozone-Depleting Substance Emitted in the 21st Century. Science (1979). 2009;326:123-5.
- 5 Liu Y, Lee-Archer P, Sheridan NM, Seglenieks R, McGain F, Eley VA. Nitrous Oxide Use in Australian Health Care: Strategies to Reduce the Climate Impact. Anesth Analg. 2023;137:819-29.
- 6 Elliott KJ, Pierce JMT. Twelve-year trend in nitrous oxide use at a tertiary institution: striving for a net zero NHS. Anaesthesia. 2021;76:1667-8.
- 7 da Silva LM, de Araújo ACLF, Defácio L, et al. Reduction in anesthesia-related nitrous oxide consumption and environmental footprint via a quality improvement initiative at two quaternary hospitals in São Paulo, Brazil. Can J Anaesth. 2025;72:1249-1259.
- 8 Isserman RS, Yuan I, Elliott EM, et al. Reducing the environmental impact of mask inductions in children: A quality improvement report. Pediatric Anesthesia. 2023;33:728-735.
- 9 Lucio LMC, Braz MG, do Nascimento Junior P, et al. Riscos ocupacionais, danos no material genético e estresse oxidativo frente à exposição aos resíduos de gases anestésicos. Brazilian Journal of Anesthesiology. 2018;68:33-41.
- 10 Rübsam M-L, Kruse P, Dietzler Y, et al. A call for immediate climate action in anesthesiology: routine use of minimal or metabolic fresh gas flow reduces our ecological footprint. Canadian Journal of Anesthesia/Journal canadien d’anesthésie. 2023;70:301-12.
- 11 Burns KEA, Duffett M, Kho ME, et al. A guide for the design and conduct of self-administered surveys of clinicians. Can Med Assoc J. 2008;179:245-52.
-
12 Axelrod D BCFJ et al. Greening the operating room and perioperative arena: environmental sustainability for anesthesia practice, 2017. American Society of Anesthesiologists. Available from URL: https://www.asahq.org/about-asa/governance-and-committees/asa-committees/committee-on-equipment-and-facilities/environmentalsustainability/greening-the-operating-room
» https://www.asahq.org/about-asa/governance-and-committees/asa-committees/committee-on-equipment-and-facilities/environmentalsustainability/greening-the-operating-room - 13 Kagoma Y, Stall N, Rubinstein E, et al. People, planet and profits: the case for greening operating rooms. Can Med Assoc J. 2012;184: 905-1911.
- 14 Kennedy RR, French RA, Vesto G, et al. The effect of fresh gas flow during induction of anaesthesia on sevoflurane usage: a quality improvement study. Anaesthesia. 2019;74:875-82.
- 15 Eysenbach G. Improving the Quality of Web Surveys: The Checklist for Reporting Results of Internet E-Surveys (CHERRIES). J Med Internet Res. 2004;6:e34.
- 16 Chesebro BB, Gandhi S. Mitigating the systemic loss of nitrous oxide: a narrative review and data-driven practice analysis. Br J Anaesth. 2024;133:1413-8.
- 17 Chakera A. Driving down embedded emissions from medical nitrous oxide. BMJ. 2021;n2922.
- 18 Chakera A, Fuhrmann A. Hospital action plan for mitigating anaesthetic nitrous oxide emissions. Br J Anaesth. 2024;133:1514-7.
- 19 Bernat M, Boyer A, Roche M, et al. Reducing the carbon footprint of general anaesthesia: a comparison of total intravenous anaesthesia vs. a mixed anaesthetic strategy in 47,157 adult patients. Anaesthesia. 2024;79:309-17.
- 20 van der Griend BFH, MacGregor AL, Currant PN, et al. An audit of inhalational anaesthetic agent usage in paediatric anaesthesia. Anaesthesia. 2022;77:1170-1.
- 21 Feldman JM. Managing Fresh Gas Flow to Reduce Environmental Contamination. Anesth Analg. 2012;114:1093-101.
-
22 Glenski T NS. Low Flow Anesthesia in Pediatric Patients. SPA One-pagers. https://pedsanesthesia.org/wp-content/uploads/2021/08/Low-Flow-Anesthesia-in-Pediatric-Patients.pdf: Society for Pediatric Anesthesia.
» https://pedsanesthesia.org/wp-content/uploads/2021/08/Low-Flow-Anesthesia-in-Pediatric-Patients.pdf - 23 Singh A, Sinha R, Aravindan A, et al. Comparison of low-fresh gas flow technique to standard technique of sevoflurane induction in children ‒ A randomized controlled trial. Pediatric Anesthesia. 2019;29:304-9.
- 24 Furlan L, Di Francesco P, Del Marco P, et al. Anesthetic gases environmental impact, anesthesiologists’ awareness, and improvement opportunities: a monocentric observational study. Journal of Anesthesia, Analgesia and Critical Care. 2024;4:47.
- 25 Petre M-A, Bahrey L, Levine M, et al. Anesthesia environmental sustainability programs ‒ a survey of Canadian department chiefs and residency program directors. Canadian Journal of Anesthesia/Journal canadien d’anesthésie. 2020;67:1190-200.
- 26 Law RG, Koh WJ, Poh PK, Htet NM, Ng SWB, Liu EHC, Ang KS. Implementation of a quality improvement project at National University Hospital Singapore to mitigate the environmental impact of nitrous oxide. Can J Anaesth. 2025;72:1260-7.
- 27 Silva MAP, Figueiredo DBS, Lara JR, et al. Evaluation of genetic instability, oxidative stress, and metabolism-related gene polymorphisms in workers exposed to waste anesthetic gases. Environmental Science and Pollution Research. 2022;30:9609-23.
- 28 Silva MAP, Carvalho LIM, Destro MV, et al. From indoors to outdoors: Impact of waste anesthetic gases on occupationally exposed professionals and related environmental hazards - A narrative review and update. Environ Toxicol Pharmacol. 2025;113:104624.
- 29 Braz MG, Souza KM, Lucio LMC, et al. Detrimental effects detected in exfoliated buccal cells from anesthesiology medical residents occupationally exposed to inhalation anesthetics: An observational study. Mutation Research/Genetic Toxicology and Environmental Mutagenesis. 2018;832-833:61-4.
- 30 Grassi TF, Silva MAP, Destro MV., et al. Environmental and biological measurements of the anesthetic isoflurane and its possible toxic effects in veterinarians. Environ Toxicol Pharmacol. 2025;114:104639.
- 31 Aun AG, Damasceno DC, Sinzato YK, et al. High anesthetic exposure leads to oxidative damage and gene expression changes in physicians during medical residency: a cohort study. Environmental Science and Pollution Research. 2023;30:73202-12.
- 32 Liu L, Liu Z, Ma C, et al. Exploring differences in symptomatic adverse events assessment between nurses and physicians in the clinical trial setting. Sci Rep. 2023;13:4917.
- 33 Agência Nacional de Vigilância Sanitária (ANVISA). Normative Instruction No. 301, of 17 May 2024. Establishes the list of medicinal gases subject to notification under RDC No. 870/2024. 22 May 2024.
- 34 Agência Nacional de Vigilância Sanitária (ANVISA). Resolution RDC No. 870, of 17 May 2024. Provides for notification, registration and post-registration changes of medicinal gases classified as medicines. 21 May 2024.
- 35 Associação Brasileira de Normas Técnicas (ABNT). ABNT NBR 15882. Medical gas mixer - Autonomous oxygen and nitrous oxide mixer for medical use - Requirements for construction, installation and operation. Rio de Janeiro, 2010.
- 36 Associação Brasileira de Normas Técnicas (ABNT). ABNT NBR 12188. Centralized medical gas pipeline systems. Rio de Janeiro, 2016.
-
Associate Editor:
Neuber Martins Fonseca