Background Increased aortic stiffness in patients with bicuspid aortic valve (BAV) may significantly affect morbidity and mortality.
Objective We aimed to evaluate aortic elasticity properties and the usability of the new technique by measuring pulse wave velocity (PWV) with a transthoracic echocardiography device in patients with BAV.
Methods Fifty patients with BAV and 50 healthy children with similar demographic characteristics were included in this study. Patients with BAV were grouped according to fused cusp morphology. Valve function was normal or near normal in the patients with BAV included in the study. All patients’ left ventricular function, aortic root diameter, and aortic elasticity characteristics were evaluated. A p-value <0.05 was considered significant.
Results PWV was significantly higher in the BAV group (p=0.000). Aortic elasticity parameters obtained from ascending aorta diameters were similar between the groups. Ascending aorta diameters were significantly higher in the BAV group. There was a correlation between PWV, ascending aortic diameter, vena contracta in aortic regurgitation, and peak aortic velocity. PWV inter- and intraobserver reliability alpha values were 0.92 and 0.84, respectively.
Conclusions In the pediatric BAV group with normal or near-normal valve function, although aortic elasticity parameters were normal with conventional measurements based on ascending aorta diameters, PWV measurements with the same device were significantly higher without the need for an additional apparatus or program, and aortic stiffness increased in the BAV group. PWV measurement by echocardiography is a reliable and reproducible technique.
Keywords
Bicuspid Aortic Valve Disease; Child; Pulse Wave Analysis

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
A medição da velocidade da onda de pulso por ecocardiografia transtorácica é prática, de fácil acesso, de baixo custo, não requer dispositivos adicionais e pode fornecer informações importantes sobre a elasticidade da aorta, mesmo em estágios iniciais, em comparação com as medições convencionais. A medição da velocidade da onda de pulso com a nova técnica apresenta concordância interobservador semelhante. VOP: velocidade da onda de pulso; VAB: válvula aórtica bicúspide
Pulse wave velocity value measurement with transthoracic echocardiography is practical, easily accessible, inexpensive, does not require additional devices, and can provide important information about aortic elasticity even in the early period compared with conventional measurements. PWV measurement with the new technique has similar inter-observer value measurements. PWV: pulse wave velocity; BAV: bicuspid aortic valve.




